FT080CF Series Installation & Operation Manual
www.ot-systems.com 10
4.2 Contact Closure (CC) connections
For Contact closure input and output connections, please note the following pin assignment:
Pin Assignment
(Screw Terminal
Block)
Data format
1
2
3
4
5
Input
Contact closure /
TTL
Input
(Hi)
Input
(Low /COM)
N/A
N/A
N/A
Output
Normally Close
(NC)
N/A
N/A
Output (Hi)
Output
(Low /COM)
N/A
Normally Open
(NO)
N/A
N/A
N/A
Output
(Low /COM)
Output
(Hi)
Contact Closure/TTL Input and Normally Close (NC) Output connection diagram:
Transmitter End Receiver End
User’s Equipment
CC (5-PIN)
CC (5-PIN)
User’s Equipment
Hi
1
Contact
Input
1
Low /COM
2
2
3
Relay
Contact
Output
3
Hi
4
4
Low /COM
5
5
Fig. 4.4.1 Connector Pin Assignments for Contact Closure/TTL input and Normally Close (NC)
ouput at CC port
Contact Closure/TTL Input and Normally Open (NO) Output connection diagram:
Transmitter End Receiver End
User’s Equipment
CC (5-PIN)
CC (5-PIN)
User’s Equipment
Hi
1
Contact
Input
1
Low /COM
2
2
3
Relay
Contact
Output
3
4
4
Low /COM
5
5
Hi
Fig. 4.4.2 Connector Pin Assignments for Contact Closure/TTL input and Normally Open (NO)
output at CC port